Time range setting | 0.1 s | 1 s | 10 s | 1 min | 10 min | 1 h | 10 h | 100 h |
---|---|---|---|---|---|---|---|---|
Set time range | 0.1 to 1.2 s | 1 to 12 s | 10 to 120 s | 1 to 12 min | 10 to 120 min |
1 to 12 h | 10 to 120 h | 100 to 1,200 h |
Scale numbers | 12 |
Power supply voltage *1 | 24 to 240 VAC/DC, 50/60 Hz *2 12 VDC *2 |
|
---|---|---|
Allowable voltage fluctuation range | 24 to 240 VAC/DC: 85% to 110% of rated voltage 12 VDC: 90% to 110% of rated voltage |
|
Power reset | Minimum power-OFF time: 0.1 s | |
Reset voltage | 10% of rated voltage *3 | |
Power consumption *4 | H3DKZ-A1 | At 240 VAC: 6.6 VA max. |
H3DKZ-A2 | At 240 VAC: 4.5 VA max. | |
Control output | Contact output, 5 A at 250 VAC with resistive load (cosφ = 1), 5 A at 30 VDC with resistive load |
|
Ambient operating temperature | -20 to 55°C (with no icing) | |
Storage temperature | -40 to 70°C (with no icing) | |
Ambient operating humidity | 25% to 85% |