Menu

THƯƠNG HIỆU

Rờ Le Thời Gian Timer Đa Chức Năng Omron H3CR-A8

  • Tình trạng: Còn hàng
  • Hãng sản xuất: Omron
  • Mã thiết bị: H3CR-A8
  • Bảo hành: 12 Tháng
  • Xuất xứ: Trung Quốc
Giá liên hệ
Quý khách vui lòng liên hệ báo giá ưu đãi đối với số lượng lớn.
Rated power supply voltage 100 to 240 VAC 50/60 Hz
100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier)
Allowable voltage variable range 85% to 110% of rated voltage
Power consumption Relay ON: Approx. 2 VA (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.3 VA (at 240 VAC 60 Hz)
Relay ON: Approx. 1.6 W (at 240 VAC 60 Hz)/Relay OFF: Approx. 1.1 W (at 240 VAC 60 Hz)
Reset voltage 10% max. of rated supply voltage
Number of time ranges 18
Operation mode ON delay, Flicker OFF start, Flicker ON start, Interval, One shot output
Control output (Type) Time-limit: DPDT
Control output (Contact output) Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC/
Inductive load (Reference value): 2 A at 250 VAC (cosφ=0.4)/3 A at 30 VDC (L/R=7 ms)
Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating resetting Time-limit operation/Self-reset
Ambient temperature range Operating: -10 to 55 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing)
Ambient humidity range Operating: 35 to 85%
Accuracy of operating time ±0.2% FS max.
±0.2% ±10 ms in a range of 1.2 s and 3 s
Setting error ±5% FS ±50 ms max.
Reset time 0.1 s max.
Influence of voltage ±0.2% FS max.
±0.2% ±10 ms in a range of 1.2 s and 3 s
Influence of temperature ±1% FS max. (±1% ±10 ms in a range of 1.2 s and 3 s)
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min
Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min
Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltage Between power terminals: 5 kV
Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunity Mulfunction: 8 kV, Destruction: 15 kV
Vibration resistance Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h
Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistance Destruction: 1,000 m/s2, 3 times each in 6 directions
Malfunction: 100 m/s2, 3 times each in 6 directions
Life expectancy (relay output) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Degree of protection Panel surface: IP40
Terminals: IP00
Connecting method 8-pin round socket
Case color Munsell 5Y7/1
Accessories Instruction manual, Compliance information sheet
Weight Approx. 90 g