| Input power: Main circuit | Single/3-phase 200 V (+10% -15%) to 240 V (+10% -15%) 50/60 Hz |
|---|---|
| Input power: Control circuit | Single phase 200 V (+10% -15%) to 240 V (+10% -15%) 50/60 Hz |
| Encoder feedback | 23-bit (8388608 resolution) absolute encoder, 7-wire serial |
| About Encoder feedback | * Since it can be used only as an incremental system, do not connect the battery for absolute encoder. Parameter Pr. 0.15 must be set to “1” (factory settings). |
| Parallel I/O connector: Control signal Input |
General purpose 10 inputs The function of general-purpose input is selected by parameters. |
| Parallel I/O connector: Control signal Output |
General purpose 6 output The function of general-purpose output is selected by parameters. |
| Parallel I/O connector: Analog signal Output |
2 outputs (Analog monitor: 2 output) |
| Parallel I/O connector: Pulse signal Input |
2 inputs (Photo-coupler input, Line receiver input) |
| Parallel I/O connector: Pulse signal Output |
4 outputs (Line driver: 3 output, open collector: 1 output) |
| Communication function | USB |
| Communication function: USB | USB interface to connect to computers for parameter setting or status monitoring. |
| Regeneration | No built-in regenerative resistor (external resistor only) |
| Control mode | Switching among the following 3 mode is enabled, (1) Position control, (2) Internal velocity command, (3) Position/Internal velocity command |