Model CL1000VB CL2000VB CL3000VB CL6000VB CL10000VB
Capacity 1kVA 2kVA 3kVA 6kVA 10kVA
INPUT
Rated input voltage 220VAC or 120VAC 220VAC
Rated input frequency 50Hz/60Hz (self-adaption)
Input voltage Range 110- 300 ± 5VAC (50% load); 140 – 295 ± 5VAC (100% load)
or 50/60/70/80 – 150 ± 5VAC (60%/70%/80%/100% load)
110- 300 ± 5VAC (50% load);
140 – 300 ± 5VAC (100%  load)
Input frequency Range 40-70Hz ± 0.5%
Phase Single phase+N+GND
Power factor >0.99
Input current (liner full load) 4.0A or 10A 8.1A or 20A 12.1A or 30A 24.2A 40.4A
THD <6% <5%
ByPass voltage range 186VAC-252VAC or 90VAC-140VAC 186VAC-252VAC
OUTPUT
Rated voltage 208/220/230/240VAC or 100/110/115/120/127VAC can be set on LCD 208/220/230/240VAC  can be set on LCD
Power factor 0.9
Voltage distortion ±1%
DC component voltage ≤200mv
Output current crest factor 3:1
RATED FREQUENCY
AC mode same as input frequency
Battery mode 50/60±0.2Hz
Phase lock speed ≤1Hz/s
Wave distortion 100% linear load <3%; 100% nonlinear load <5%
TRANSFER TIME
From Mains mode to battery mode 0ms
From battery mode to Mains mode 0ms
From Mains mode to Bypass mode <4ms <0ms
From Bypass mode to Mains mode <4ms <0ms
From normal mode to ECO mode <10ms <10ms
System

Efficiency

Full load >90% >92%
ECO mode >94%
Inverter overload capacity 105% —150% 60s transfer to bypass mode giving alarm; > 150% 300ms transfer to bypass mode giving alarm
BATTERY
Battery type Lead acid maintenance free battery
DC voltage 24V DC/36V DC 48V DC/ 72V DC 72V DC /96VDC 192V DC /240V DC 192V DC /240V DC
Inbuilt battery 9Ah/12V 9Ah/12V 9Ah /12V 7.5Ah/12V 9Ah/12V
Battery quantity 2/3 4/6 6/ 8 16/20 16/20
CHARGER
Output voltage 27.5±0.4V 55+0.6V 82.5+0.9V 193.7+0.9V
CHARGER METHOD Three – stage charging
Input voltage range 80VAC-300VAC or 40VAC-150VAC 150 VAC-300VAC
Charger current Standard model:1A; Long time model: 6A (Option 12A) Standard model:1A; Long time model: 8A
Protect Overheat protection, fan test protection
L-N false protection, phase difference protection, output overload protection
Mute, cold start, auto start AC, EPO
Control RS232; SNMP card; USB (default only RS232)
The Communications Functional software, status analysis, turn on, turn off the UPS system
monitor UPS working status, historical storage
Display LCD/LED
SYSTEM OPERATING ENVIRONMENT
Operating environment Operation tem. 0 – 40 0C
Store tem. 250C – 550C
Humidity 20 – 90% (non – condensing)
Altitude 0m- 1500m, over 1500m, used with power derated
Noise <45db <50db
UPS dimension
(W*D*H) mm
Long time 144x357x215 190x452x341 262x514x455
Standard 262x514x735
Packing dimen- sion (W*D*H) mm Long time 230x445x315 320x550x462 365x605x510
Standard 390x625x937
Net/Gross
Weight (kg)
Long time 5.6/6.9 11/13 11.6/137 22.1/25.2 22.8/25.9